staging: comedi: ni_mio_common: fix AO timer off-by-one regression
As reported by Éric Piel on the Comedi mailing list (see
<https://groups.google.com/forum/#!topic/comedi_list/ueZiR7vTLOU/discussion>),
the analog output asynchronous commands are running too fast with a
period 50 ns shorter than it should be. This affects all boards with AO
command support that are supported by the "ni_pcimio", "ni_atmio", and
"ni_mio_cs" drivers.
This is a regression bug introduced by commit
080e6795cba3 ("staging:
comedi: ni_mio_common: Cleans up/clarifies ni_ao_cmd"), specifically,
this line in `ni_ao_cmd_set_update()`:
/* following line: N-1 per STC */
ni_stc_writel(dev, trigvar - 1, NISTC_AO_UI_LOADA_REG);
The `trigvar` variable value comes from a call to `ni_ns_to_timer()`
which converts a timer period in nanoseconds to a hardware divisor
value. The function already reduces the divisor by 1 as required by the
hardware, so the above line should not reduce it further by 1. Fix it
by replacing `trigvar` by `trigvar - 1` in the above line, and remove
the misleading comment.
Reported-by: Éric Piel <piel@delmic.com>
Fixes: 080e6795cba3 ("staging: comedi: ni_mio_common: Cleans up/clarifies ni_ao_cmd")
Cc: Éric Piel <piel@delmic.com>
Cc: Spencer E. Olson <olsonse@umich.edu>
Cc: <stable@vger.kernel.org> # 4.7+
Signed-off-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>