bnx2x: Prevent false warning for lack of FC NPIV
authorYuval Mintz <Yuval.Mintz@qlogic.com>
Tue, 15 Mar 2016 17:52:04 +0000 (19:52 +0200)
committerDavid S. Miller <davem@davemloft.net>
Fri, 18 Mar 2016 23:17:16 +0000 (19:17 -0400)
commit1e6bb1a3540fec3ef112b9a89dda88e684c3ff59
tree9af4fcb2dcaf852adb567f0441e46f72e8ee5d6a
parent38c848c73180fb1d142a39e664b6d9663751f6b2
bnx2x: Prevent false warning for lack of FC NPIV

Not all adapters have FC-NPIV configured. If bnx2fc is used with such an
adapter, driver would read irrelevant data from the the nvram and log
"FC-NPIV table with bad length..." In system logs.

Simply accept that reading '0' as the feature offset in nvram indicates
the feature isn't there and return.

Reported-by: Andrew Patterson <andrew.patterson@hpe.com>
Signed-off-by: Yuval Mintz <Yuval.Mintz@qlogic.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c