scsi: hisi_sas: shutdown axi bus to avoid exception CQ returned
authorXiang Chen <chenxiang66@hisilicon.com>
Fri, 25 Jan 2019 14:22:31 +0000 (22:22 +0800)
committerMartin K. Petersen <martin.petersen@oracle.com>
Tue, 29 Jan 2019 06:41:20 +0000 (01:41 -0500)
commit5c31b0c677531c2b8b4e29b3cfb923df663f39b7
tree6945702922ad17f67a1b2169bdbdcd98d0a8705c
parent569eddcf3a0f4efff4ef96a7012010e0f7daa8b4
scsi: hisi_sas: shutdown axi bus to avoid exception CQ returned

When injecting 2 bit ECC error, it will cause fatal AXI interrupts. Before
the recovery of SAS controller reset, the internal of SAS controller is in
error. If CQ interrupts return at the time, actually it is exception CQ
interrupt, and it may cause resource release in disorder.

To avoid the exception situation, shutdown AXI bus after fatal AXI
interrupt. In SAS controller reset, it will restart AXI bus. For later
version of v3 hw, hardware will shutdown AXI bus for this situation, so
just fix current ver of v3 hw.

Signed-off-by: Xiang Chen <chenxiang66@hisilicon.com>
Signed-off-by: John Garry <john.garry@huawei.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
drivers/scsi/hisi_sas/hisi_sas_v3_hw.c