TTY: synclink: Convert + to | for bit operations
Dan Carpenter noticed a missing set of parentheses
around a multiple field addition.
https://lkml.org/lkml/2013/1/27/166
His original commit message:
There is a kind of precedence problem here, but it doesn't affect how
the code works because ->serial_signals is unsigned char. We want to
clear two flags here.
#define SerialSignal_RTS 0x20 /* Request to Send */
#define SerialSignal_DTR 0x80 /* Data Terminal Ready */
Without the parenthesis then it does:
info->serial_signals &= 0x5f;
With the parenthesis it does:
info->serial_signals &= 0xffffff5f;
info->serial_signals is an unsigned char so the two statements are
equivalent, but it's cleaner to add the parenthesis. In other dtr_rts()
functions the parenthesis are there so this makes it more consistent.
Other changes:
Convert all + uses to | for these bit operations.
Reorder the multiple fields for consistency.
Update the comments too.
Reported-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Joe Perches <joe@perches.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>