rtc-x1205: reset clock to sane state after power failure
authorJohannes Weiner <jw@emlix.com>
Tue, 1 Dec 2009 21:17:49 +0000 (13:17 -0800)
committerLinus Torvalds <torvalds@linux-foundation.org>
Wed, 2 Dec 2009 00:32:20 +0000 (16:32 -0800)
commitcb8799eeddd542abd504c62c11014dfbaec7f3a1
tree0b7840419fd006bb6f61dbcbe412f5af0ab60b51
parent48a7f7746875425797aea31ed2910088635c1c7a
rtc-x1205: reset clock to sane state after power failure

When detecting power failure, the probe function would reset the clock
time to defined state.

However, the clock's _date_ might still be bogus and a subsequent probe
fails when sanity-checking these values.

Change the power-failure fixup code to do a full setting of rtc_time,
including a valid date.

Signed-off-by: Johannes Weiner <jw@emlix.com>
Cc: Alessandro Zummo <a.zummo@towertech.it>
Cc: Paul Gortmaker <p_gortmaker@yahoo.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
drivers/rtc/rtc-x1205.c