tools/power turbostat: Intel Xeon x200: fix erroneous bclk value
authorChrzaniuk, Hubert <hubert.chrzaniuk@intel.com>
Wed, 10 Feb 2016 15:35:17 +0000 (16:35 +0100)
committerLen Brown <len.brown@intel.com>
Sun, 13 Mar 2016 07:55:37 +0000 (03:55 -0400)
x200 does not enable any way to programmatically obtain bus clock
speed. Bclk for the architecture has a fixed value of 100 MHz.
At the same time x200 cannot be included in has_snb_msrs since
it does not support C7 idle state.

prior to this patch, MHz values reported on this chip
were erroneously calculated using bclk of 133MHz,
causing MHz values to be reported 33% higher than actual.

Signed-off-by: Hubert Chrzaniuk <hubert.chrzaniuk@intel.com>
Signed-off-by: Len Brown <len.brown@intel.com>
tools/power/x86/turbostat/turbostat.c

index e411cc4351374e2fa375702203c9a8fbc9540eff..652d08df5d12d6ad6bfb931b3b541b0960934ec6 100644 (file)
@@ -2697,7 +2697,7 @@ double slm_bclk(void)
 
 double discover_bclk(unsigned int family, unsigned int model)
 {
-       if (has_snb_msrs(family, model))
+       if (has_snb_msrs(family, model) || is_knl(family, model))
                return 100.00;
        else if (is_slm(family, model))
                return slm_bclk();