Errata Title:
i874: TIMER5/6/7/8 interrupts not propagated
Description:
When TIMER5, TIMER6, TIMER7, or TIMER8 clocks are enabled
(CM_IPU_TIMER5/6/7/8_CLKCTRL[0:1]MODULEMODE=0x2:ENABLE) and the CD-IPU
is in HW_AUTO mode (CM_IPU_CLKSTCTRL[0:1]CLKTRCTRL=0x3:HW_AUTO) the
corresponding TIMER will continue counting, but enabled interrupts
will not be propagated to the destinations (MPU, DSP, etc) in the
SoC until the TIMER registers are accessed from the CPUs (MPU, DSP
etc.). This can result in missed timer interrupts.
Workaround:
In order for TIMER5/6/7/8 interrupts to be propagated and serviced
correctly the CD_IPU domain should be set to SW_WKUP mode
(CM_IPU_CLKSTCTRL[0:1]CLKTRCTRL=0x2:SW_WKUP).
The above workaround is achieved by switching the IPU clockdomain
flags from HWSUP_SWSUP to SWSUP only.
Signed-off-by: Keerthy <j-keerthy@ti.com>
Signed-off-by: Suman Anna <s-anna@ti.com>
Signed-off-by: Paul Walmsley <paul@pwsan.com>
.cm_inst = DRA7XX_CM_CORE_AON_IPU_INST,
.clkdm_offs = DRA7XX_CM_CORE_AON_IPU_IPU_CDOFFS,
.dep_bit = DRA7XX_IPU_STATDEP_SHIFT,
- .flags = CLKDM_CAN_HWSUP_SWSUP,
+ .flags = CLKDM_CAN_SWSUP,
};
static struct clockdomain mpu1_7xx_clkdm = {