/* Magic constants */
#define MLX90632_ID_MEDICAL 0x0105 /* EEPROM DSPv5 Medical device id */
#define MLX90632_ID_CONSUMER 0x0205 /* EEPROM DSPv5 Consumer device id */
+#define MLX90632_DSP_VERSION 5 /* DSP version */
+#define MLX90632_DSP_MASK GENMASK(7, 0) /* DSP version in EE_VERSION */
#define MLX90632_RESET_CMD 0x0006 /* Reset sensor (address or global) */
#define MLX90632_REF_12 12LL /**< ResCtrlRef value of Ch 1 or Ch 2 */
#define MLX90632_REF_3 12LL /**< ResCtrlRef value of Channel 3 */
} else if (read == MLX90632_ID_CONSUMER) {
dev_dbg(&client->dev,
"Detected Consumer EEPROM calibration %x\n", read);
+ } else if ((read & MLX90632_DSP_MASK) == MLX90632_DSP_VERSION) {
+ dev_dbg(&client->dev,
+ "Detected Unknown EEPROM calibration %x\n", read);
} else {
dev_err(&client->dev,
- "EEPROM version mismatch %x (expected %x or %x)\n",
- read, MLX90632_ID_CONSUMER, MLX90632_ID_MEDICAL);
+ "Wrong DSP version %x (expected %x)\n",
+ read, MLX90632_DSP_VERSION);
return -EPROTONOSUPPORT;
}