Anthoine reported:
The period used by Windows change over time but it can be 1
milliseconds or less. I saw the limit_periodic_timer_frequency
print so 500 microseconds is sometimes reached.
As suggested by Paolo, lower the default timer frequency limit to a
smaller interval of 200 us (5000 Hz) to leave some headroom. This
is required due to Windows 10 changing the scheduler tick limit
from 1024 Hz to 2048 Hz.
Reported-by: Anthoine Bourgeois <anthoine.bourgeois@blade-group.com>
Suggested-by: Paolo Bonzini <pbonzini@redhat.com>
Reviewed-by: Darren Kenny <darren.kenny@oracle.com>
Cc: Paolo Bonzini <pbonzini@redhat.com>
Cc: Radim Krčmář <rkrcmar@redhat.com>
Cc: Anthoine Bourgeois <anthoine.bourgeois@blade-group.com>
Cc: Darren Kenny <darren.kenny@oracle.com>
Cc: Jan Kiszka <jan.kiszka@web.de>
Signed-off-by: Wanpeng Li <wanpengli@tencent.com>
Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
static bool __read_mostly report_ignored_msrs = true;
module_param(report_ignored_msrs, bool, S_IRUGO | S_IWUSR);
-unsigned int min_timer_period_us = 500;
+unsigned int min_timer_period_us = 200;
module_param(min_timer_period_us, uint, S_IRUGO | S_IWUSR);
static bool __read_mostly kvmclock_periodic_sync = true;