ALSA: firewire-lib: fix initial value of data block count for IR context without...
authorTakashi Sakamoto <o-takashi@sakamocchi.jp>
Sun, 7 Jul 2019 12:07:55 +0000 (21:07 +0900)
committerTakashi Iwai <tiwai@suse.de>
Mon, 8 Jul 2019 12:50:38 +0000 (14:50 +0200)
For IR context, ALSA IEC 61883-1/6 engine uses initial value of data
block counter as UINT_MAX, to detect first isochronous packet in the
middle of packet streaming.

At present, when CIP_DBC_IS_END_EVENT is not used (i.e. for drivers except
for ALSA fireworks driver), the initial value is used as is for
tracepoints event. However, the engine can detect the value of dbc field
in the payload of first isochronous packet and the value should be assigned
to the event.

This commit fixes the bug.

Fixes: 76864868dbab ("ALSA: firewire-lib: cache next data_block_counter after probing tracepoints event for IR context")
Signed-off-by: Takashi Sakamoto <o-takashi@sakamocchi.jp>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
sound/firewire/amdtp-stream.c

index b60cf25ee5a819693e19e165ec50544f9d2c5bad..3d410057eaa48f033de83001baa61e51c3356e94 100644 (file)
@@ -654,8 +654,10 @@ static int parse_ir_ctx_header(struct amdtp_stream *s, unsigned int cycle,
                        *dbc = 0;
        }
 
-       if (err >= 0 && s->flags & CIP_DBC_IS_END_EVENT)
-               s->data_block_counter = *dbc;
+       if (err < 0)
+               return err;
+
+       s->data_block_counter = *dbc;
 
        trace_amdtp_packet(s, cycle, cip_header, *payload_length, *data_blocks,
                           index);