* amax - the current
* Buck has 2 kinds of voltage steps. It is easy to find voltage by ranges,
* not the constant voltage table.
+ * n_volt - Number of available selectors
*/
-#define PM800_BUCK(vreg, ereg, ebit, amax, volt_ranges) \
+#define PM800_BUCK(vreg, ereg, ebit, amax, volt_ranges, n_volt) \
{ \
.desc = { \
.name = #vreg, \
.type = REGULATOR_VOLTAGE, \
.id = PM800_ID_##vreg, \
.owner = THIS_MODULE, \
+ .n_voltages = n_volt, \
.linear_ranges = volt_ranges, \
.n_linear_ranges = ARRAY_SIZE(volt_ranges), \
.vsel_reg = PM800_##vreg, \
/* The array is indexed by id(PM800_ID_XXX) */
static struct pm800_regulator_info pm800_regulator_info[] = {
- PM800_BUCK(BUCK1, BUCK_ENA, 0, 3000000, buck1_volt_range),
- PM800_BUCK(BUCK2, BUCK_ENA, 1, 1200000, buck2_5_volt_range),
- PM800_BUCK(BUCK3, BUCK_ENA, 2, 1200000, buck2_5_volt_range),
- PM800_BUCK(BUCK4, BUCK_ENA, 3, 1200000, buck2_5_volt_range),
- PM800_BUCK(BUCK5, BUCK_ENA, 4, 1200000, buck2_5_volt_range),
+ PM800_BUCK(BUCK1, BUCK_ENA, 0, 3000000, buck1_volt_range, 0x55),
+ PM800_BUCK(BUCK2, BUCK_ENA, 1, 1200000, buck2_5_volt_range, 0x73),
+ PM800_BUCK(BUCK3, BUCK_ENA, 2, 1200000, buck2_5_volt_range, 0x73),
+ PM800_BUCK(BUCK4, BUCK_ENA, 3, 1200000, buck2_5_volt_range, 0x73),
+ PM800_BUCK(BUCK5, BUCK_ENA, 4, 1200000, buck2_5_volt_range, 0x73),
PM800_LDO(LDO1, LDO_ENA1_1, 0, 200000, ldo1_volt_table),
PM800_LDO(LDO2, LDO_ENA1_1, 1, 10000, ldo2_volt_table),