net: dsa: sja1105: Add support for configuring address ageing time
authorVladimir Oltean <olteanv@gmail.com>
Thu, 2 May 2019 20:23:36 +0000 (23:23 +0300)
committerDavid S. Miller <davem@davemloft.net>
Fri, 3 May 2019 14:49:17 +0000 (10:49 -0400)
If STP is active, this setting is applied on bridged ports each time an
Ethernet link is established (topology changes).

Since the setting is global to the switch and a reset is required to
change it, resets are prevented if the new callback does not change the
value that the hardware already is programmed for.

Signed-off-by: Vladimir Oltean <olteanv@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/dsa/sja1105/sja1105.h
drivers/net/dsa/sja1105/sja1105_main.c

index 38506bde83c6793542565939b83e9ffc16aa52f1..0489d9adf9577230bc22b1c2f0b663d8e3dd0630 100644 (file)
 #define SJA1105_NUM_PORTS              5
 #define SJA1105_NUM_TC                 8
 #define SJA1105ET_FDB_BIN_SIZE         4
+/* The hardware value is in multiples of 10 ms.
+ * The passed parameter is in multiples of 1 ms.
+ */
+#define SJA1105_AGEING_TIME_MS(ms)     ((ms) / 10)
 
 /* Keeps the different addresses between E/T and P/Q/R/S */
 struct sja1105_regs {
index 28b11c7a81e702c5614161689c19a1775635dbe6..f5205ce85dbe2dac9e9eee72da3ca70318361f31 100644 (file)
@@ -193,8 +193,8 @@ static int sja1105_init_l2_lookup_params(struct sja1105_private *priv)
 {
        struct sja1105_table *table;
        struct sja1105_l2_lookup_params_entry default_l2_lookup_params = {
-               /* TODO Learned FDB entries are never forgotten */
-               .maxage = 0,
+               /* Learned FDB entries are forgotten after 300 seconds */
+               .maxage = SJA1105_AGEING_TIME_MS(300000),
                /* All entries within a FDB bin are available for learning */
                .dyn_tbsz = SJA1105ET_FDB_BIN_SIZE,
                /* 2^8 + 2^5 + 2^3 + 2^2 + 2^1 + 1 in Koopman notation */
@@ -1249,10 +1249,35 @@ static int sja1105_setup(struct dsa_switch *ds)
        return 0;
 }
 
+/* The MAXAGE setting belongs to the L2 Forwarding Parameters table,
+ * which cannot be reconfigured at runtime. So a switch reset is required.
+ */
+static int sja1105_set_ageing_time(struct dsa_switch *ds,
+                                  unsigned int ageing_time)
+{
+       struct sja1105_l2_lookup_params_entry *l2_lookup_params;
+       struct sja1105_private *priv = ds->priv;
+       struct sja1105_table *table;
+       unsigned int maxage;
+
+       table = &priv->static_config.tables[BLK_IDX_L2_LOOKUP_PARAMS];
+       l2_lookup_params = table->entries;
+
+       maxage = SJA1105_AGEING_TIME_MS(ageing_time);
+
+       if (l2_lookup_params->maxage == maxage)
+               return 0;
+
+       l2_lookup_params->maxage = maxage;
+
+       return sja1105_static_config_reload(priv);
+}
+
 static const struct dsa_switch_ops sja1105_switch_ops = {
        .get_tag_protocol       = sja1105_get_tag_protocol,
        .setup                  = sja1105_setup,
        .adjust_link            = sja1105_adjust_link,
+       .set_ageing_time        = sja1105_set_ageing_time,
        .get_strings            = sja1105_get_strings,
        .get_ethtool_stats      = sja1105_get_ethtool_stats,
        .get_sset_count         = sja1105_get_sset_count,