libata: fix unexpectedly frozen port after ata_eh_reset()
authorTejun Heo <tj@kernel.org>
Wed, 25 May 2011 11:19:39 +0000 (13:19 +0200)
committerJeff Garzik <jgarzik@pobox.com>
Tue, 7 Jun 2011 19:55:55 +0000 (15:55 -0400)
To work around controllers which can't properly plug events while
reset, ata_eh_reset() clears error states and ATA_PFLAG_EH_PENDING
after reset but before RESET is marked done.  As reset is the final
recovery action and full verification of devices including onlineness
and classfication match is done afterwards, this shouldn't lead to
lost devices or missed hotplug events.

Unfortunately, it forgot to thaw the port when clearing EH_PENDING, so
if the condition happens after resetting an empty port, the port could
be left frozen and EH will end without thawing it, making the port
unresponsive to further hotplug events.

Thaw if the port is frozen after clearing EH_PENDING.  This problem is
reported by Bruce Stenning in the following thread.

 http://thread.gmane.org/gmane.linux.kernel/1123265

stable: I think we should weather this patch a bit longer in -rcX
before sending it to -stable.  Please wait at least a month
after this patch makes upstream.  Thanks.

-v2: Fixed spelling in the comment per Dave Howorth.

Signed-off-by: Tejun Heo <tj@kernel.org>
Reported-by: Bruce Stenning <b.stenning@indigovision.com>
Cc: stable@kernel.org
Cc: Dave Howorth <dhoworth@mrc-lmb.cam.ac.uk>
Signed-off-by: Jeff Garzik <jgarzik@pobox.com>
drivers/ata/libata-eh.c

index dfb6e9d3d759921419d8713fc7c48764ad943207..7f099d6e4e0bca601f26f83597e01ec185f03d54 100644 (file)
@@ -2802,10 +2802,11 @@ int ata_eh_reset(struct ata_link *link, int classify,
        }
 
        /*
-        * Some controllers can't be frozen very well and may set
-        * spuruious error conditions during reset.  Clear accumulated
-        * error information.  As reset is the final recovery action,
-        * nothing is lost by doing this.
+        * Some controllers can't be frozen very well and may set spurious
+        * error conditions during reset.  Clear accumulated error
+        * information and re-thaw the port if frozen.  As reset is the
+        * final recovery action and we cross check link onlineness against
+        * device classification later, no hotplug event is lost by this.
         */
        spin_lock_irqsave(link->ap->lock, flags);
        memset(&link->eh_info, 0, sizeof(link->eh_info));
@@ -2814,6 +2815,9 @@ int ata_eh_reset(struct ata_link *link, int classify,
        ap->pflags &= ~ATA_PFLAG_EH_PENDING;
        spin_unlock_irqrestore(link->ap->lock, flags);
 
+       if (ap->pflags & ATA_PFLAG_FROZEN)
+               ata_eh_thaw_port(ap);
+
        /*
         * Make sure onlineness and classification result correspond.
         * Hotplug could have happened during reset and some