On s390 this test case fails because the socket identifiction numbers
assigned to the CPU are higher than the CPU identification numbers.
F/ix this by adding the platform architecture into the perf data header
flag information. This helps identifiing the test platform and handles
s390 specifics in process_cpu_topology().
Before:
[root@p23lp27 perf]# perf test -vvvvv -F 39
39: Session topology :
--- start ---
templ file: /tmp/perf-test-iUv755
socket_id number is too big.You may need to upgrade the perf tool.
---- end ----
Session topology: Skip
[root@p23lp27 perf]#
After:
[root@p23lp27 perf]# perf test -vvvvv -F 39
39: Session topology :
--- start ---
templ file: /tmp/perf-test-8X8VTs
CPU 0, core 0, socket 6
CPU 1, core 1, socket 3
---- end ----
Session topology: Ok
[root@p23lp27 perf]#
Signed-off-by: Thomas Richter <tmricht@linux.ibm.com>
Reviewed-by: Hendrik Brueckner <brueckner@linux.ibm.com>
Cc: Heiko Carstens <heiko.carstens@de.ibm.com>
Cc: Martin Schwidefsky <schwidefsky@de.ibm.com>
Fixes: c84974ed9fb6 ("perf test: Add entry to test cpu topology")
Link: http://lkml.kernel.org/r/20180611073153.15592-2-tmricht@linux.ibm.com
Signed-off-by: Arnaldo Carvalho de Melo <acme@redhat.com>
perf_header__set_feat(&session->header, HEADER_CPU_TOPOLOGY);
perf_header__set_feat(&session->header, HEADER_NRCPUS);
+ perf_header__set_feat(&session->header, HEADER_ARCH);
session->header.data_size += DATA_SIZE;