When the scsi_dh_alua handler issues an RTPG during initialization, if it gets
0x06/0x29/0x04 as the sense, it will fail to attach the handler. NetApp
E-Series returns 0x29/0x00 for power on, and 0x29/0x04 for conditions that
cause the controller to reboot again. These conditions should be treated
identically within the handler.
Signed-off-by: Sean Stewart <Sean.Stewart@netapp.com>
Acked-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
* Power On, Reset, or Bus Device Reset, just retry.
*/
return ADD_TO_MLQUEUE;
+ if (sense_hdr->asc == 0x29 && sense_hdr->ascq == 0x04)
+ /*
+ * Device internal reset
+ */
+ return ADD_TO_MLQUEUE;
if (sense_hdr->asc == 0x2a && sense_hdr->ascq == 0x01)
/*
* Mode Parameters Changed