Bluetooth: Remove page timeout setting from HCI init sequence
authorJohan Hedberg <johan.hedberg@nokia.com>
Mon, 10 Jan 2011 12:28:45 +0000 (14:28 +0200)
committerGustavo F. Padovan <padovan@profusion.mobi>
Tue, 8 Feb 2011 03:40:06 +0000 (01:40 -0200)
User space should set the page timeout so there's no need to explicitly
set it in the HCI init sequence. Even if user space fails to set it the
controller default value will be used.

Signed-off-by: Johan Hedberg <johan.hedberg@nokia.com>
Signed-off-by: Gustavo F. Padovan <padovan@profusion.mobi>
net/bluetooth/hci_core.c

index cedb8a966df6568b6eb53a1d2883e3ea8352c569..748f5a65caf4d871cf748a0a9b9cc28f5f9faf5f 100644 (file)
@@ -254,10 +254,6 @@ static void hci_init_req(struct hci_dev *hdev, unsigned long opt)
        flt_type = HCI_FLT_CLEAR_ALL;
        hci_send_cmd(hdev, HCI_OP_SET_EVENT_FLT, 1, &flt_type);
 
-       /* Page timeout ~20 secs */
-       param = cpu_to_le16(0x8000);
-       hci_send_cmd(hdev, HCI_OP_WRITE_PG_TIMEOUT, 2, &param);
-
        /* Connection accept timeout ~20 secs */
        param = cpu_to_le16(0x7d00);
        hci_send_cmd(hdev, HCI_OP_WRITE_CA_TIMEOUT, 2, &param);