The "or" condition (clk_freq != TRF7970A_27MHZ_CLOCK_FREQUENCY) ||
(clk_freq != TRF7970A_13MHZ_CLOCK_FREQUE) will always be true because
clk_freq cannot be equal to two different values at the same time. Use
the && operator instead of || to fix this.
Detected by CoverityScan, CID#
1430468 ("Constant expression result")
Fixes: 837eb4d21ecde7 ("NFC: trf7970a: add device tree option for 27MHz clock")
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Acked-by: Geoff Lansberry <geoff@kuvee.com>
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
}
of_property_read_u32(np, "clock-frequency", &clk_freq);
- if ((clk_freq != TRF7970A_27MHZ_CLOCK_FREQUENCY) ||
+ if ((clk_freq != TRF7970A_27MHZ_CLOCK_FREQUENCY) &&
(clk_freq != TRF7970A_13MHZ_CLOCK_FREQUENCY)) {
dev_err(trf->dev,
"clock-frequency (%u Hz) unsupported\n", clk_freq);