From: Matthias Reichl Date: Wed, 8 Nov 2017 20:03:31 +0000 (+0100) Subject: ASoC: bcm2835: Support additional samplerates up to 384kHz X-Git-Url: http://git.cdn.openwrt.org/?a=commitdiff_plain;h=675c0ee514f56ea39f6f550299621aafe9a53fc0;p=openwrt%2Fstaging%2Fblogic.git ASoC: bcm2835: Support additional samplerates up to 384kHz Sample rates are only restricted by the capabilities of the clock driver, so use SNDRV_PCM_RATE_CONTINUOUS instead of SNDRV_PCM_RATE_8000_192000. Tests (eg with pcm5122) have shown that bcm2835 works fine in 384kHz/32bit stereo mode, so change the maximum allowed rate from 192kHz to 384kHz. Signed-off-by: Matthias Reichl Reviewed-by: Eric Anholt Signed-off-by: Mark Brown --- diff --git a/sound/soc/bcm/bcm2835-i2s.c b/sound/soc/bcm/bcm2835-i2s.c index dcacf7f83c93..f4b778ed350b 100644 --- a/sound/soc/bcm/bcm2835-i2s.c +++ b/sound/soc/bcm/bcm2835-i2s.c @@ -719,7 +719,9 @@ static struct snd_soc_dai_driver bcm2835_i2s_dai = { .playback = { .channels_min = 2, .channels_max = 2, - .rates = SNDRV_PCM_RATE_8000_192000, + .rates = SNDRV_PCM_RATE_CONTINUOUS, + .rate_min = 8000, + .rate_max = 384000, .formats = SNDRV_PCM_FMTBIT_S16_LE | SNDRV_PCM_FMTBIT_S24_LE | SNDRV_PCM_FMTBIT_S32_LE @@ -727,7 +729,9 @@ static struct snd_soc_dai_driver bcm2835_i2s_dai = { .capture = { .channels_min = 2, .channels_max = 2, - .rates = SNDRV_PCM_RATE_8000_192000, + .rates = SNDRV_PCM_RATE_CONTINUOUS, + .rate_min = 8000, + .rate_max = 384000, .formats = SNDRV_PCM_FMTBIT_S16_LE | SNDRV_PCM_FMTBIT_S24_LE | SNDRV_PCM_FMTBIT_S32_LE