From: Adrian Schmutzler Date: Fri, 21 Feb 2020 20:09:25 +0000 (+0100) Subject: kirkwood: do not expose status LED to user config by default X-Git-Url: http://git.cdn.openwrt.org/?a=commitdiff_plain;h=aa9c2149a77652e803939e1fc77dac5d35488cac;p=openwrt%2Fstaging%2Fthess.git kirkwood: do not expose status LED to user config by default So far, the state of status LEDs is set up in 01_leds for many devices in kirkwood target. As those LEDs are also controlled by diag.sh, exposing them to the user via uci config by default seems not helpful and might even have confusing results for the user. Thus, remove the ucidef_set_led_default setup for power/status LED, but do not touch the rest where user control is actually a feature. Signed-off-by: Adrian Schmutzler --- diff --git a/target/linux/kirkwood/base-files/etc/board.d/01_leds b/target/linux/kirkwood/base-files/etc/board.d/01_leds index 504be16480..bba845eae5 100755 --- a/target/linux/kirkwood/base-files/etc/board.d/01_leds +++ b/target/linux/kirkwood/base-files/etc/board.d/01_leds @@ -10,41 +10,18 @@ board_config_update board=$(board_name) case "$board" in -"cloudengines,pogoe02") - ucidef_set_led_default "health" "health" "pogo_e02:green:health" "1" - ucidef_set_led_default "fault" "fault" "pogo_e02:orange:fault" "1" - ;; "iom,ix2-200") ucidef_set_led_timer "health" "health" "status:white:rebuild_led" "200" "800" ;; -"linksys,audi") - ucidef_set_led_default "power" "power" "audi:green:power" "1" - ;; "linksys,viper") - ucidef_set_led_default "health" "health" "viper:white:health" "1" ucidef_set_led_default "pulse" "pulse" "viper:white:pulse" "1" ;; -"raidsonic,ib-nas62x0") - ucidef_set_led_default "health" "health" "ib62x0:green:os" "1" - ucidef_set_led_default "fault" "fault" "ib62x0:red:os" "1" - ;; -"seagate,dockstar") - ucidef_set_led_default "health" "health" "status:green:health" "1" - ucidef_set_led_default "fault" "fault" "status:orange:fault" "1" - ;; -"seagate,goflexhome"|\ -"seagate,goflexnet") - ucidef_set_led_default "health" "health" "status:green:health" "1" - ucidef_set_led_default "fault" "fault" "status:orange:fault" "0" - ;; "zyxel,nsa310b") - ucidef_set_led_default "health" "health" "nsa310:green:sys" "1" ucidef_set_led_usbhost "usb" "USB" "nsa310:green:usb" ucidef_set_led_ataport "hdd" "HDD" "nsa310:green:hdd" "1" ucidef_set_led_ataport "esata" "eSata" "nsa310:green:esata" "2" ;; "zyxel,nsa325") - ucidef_set_led_default "health" "health" "nsa325:green:sys" "1" ucidef_set_led_usbhost "usb" "USB" "nsa325:green:usb" ucidef_set_led_ataport "hdd1" "HDD1" "nsa325:green:hdd1" "1" ucidef_set_led_ataport "hdd2" "HDD2" "nsa325:green:hdd2" "2"