From 4101ecc23db90ae7e9b2a4b1cfe4aaf37405b4a8 Mon Sep 17 00:00:00 2001 From: Thomas Gleixner Date: Mon, 13 Apr 2015 16:43:35 +0200 Subject: [PATCH] power: reset: ltc2952: Remove bogus hrtimer_start() return value checks The return value of hrtimer_start() tells whether the timer was inactive or active already when hrtimer_start() was called. The code emits a bogus warning if the timer was active already claiming that the timer could not be started. Remove it along with the bogus comment in the else path. Signed-off-by: Thomas Gleixner Acked-by: Frans Klaver Cc: Sebastian Reichel Cc: Dmitry Eremin-Solenikov Cc: David Woodhouse Cc: Wolfram Sang Cc: linux-pm@vger.kernel.org --- drivers/power/reset/ltc2952-poweroff.c | 19 +++---------------- 1 file changed, 3 insertions(+), 16 deletions(-) diff --git a/drivers/power/reset/ltc2952-poweroff.c b/drivers/power/reset/ltc2952-poweroff.c index 7ef193b6f7fe..5f855f99bdfc 100644 --- a/drivers/power/reset/ltc2952-poweroff.c +++ b/drivers/power/reset/ltc2952-poweroff.c @@ -120,18 +120,7 @@ static enum hrtimer_restart ltc2952_poweroff_timer_wde(struct hrtimer *timer) static void ltc2952_poweroff_start_wde(struct ltc2952_poweroff *data) { - if (hrtimer_start(&data->timer_wde, data->wde_interval, - HRTIMER_MODE_REL)) { - /* - * The device will not toggle the watchdog reset, - * thus shut down is only safe if the PowerPath controller - * has a long enough time-off before triggering a hardware - * power-off. - * - * Only sending a warning as the system will power-off anyway - */ - dev_err(data->dev, "unable to start the timer\n"); - } + hrtimer_start(&data->timer_wde, data->wde_interval, HRTIMER_MODE_REL); } static enum hrtimer_restart @@ -165,12 +154,10 @@ static irqreturn_t ltc2952_poweroff_handler(int irq, void *dev_id) } if (gpiod_get_value(data->gpio_trigger)) { - if (hrtimer_start(&data->timer_trigger, data->trigger_delay, - HRTIMER_MODE_REL)) - dev_err(data->dev, "unable to start the wait timer\n"); + hrtimer_start(&data->timer_trigger, data->trigger_delay, + HRTIMER_MODE_REL); } else { hrtimer_cancel(&data->timer_trigger); - /* omitting return value check, timer should have been valid */ } return IRQ_HANDLED; } -- 2.30.2