From 7407188489c62a7b5694bc75a6db2b82af94c9a5 Mon Sep 17 00:00:00 2001 From: Anson Huang Date: Thu, 19 Apr 2018 14:04:43 +0800 Subject: [PATCH] clocksource/imx-tpm: Correct -ETIME return condition check The additional brakects added to tpm_set_next_event's return value computation causes (int) forced type conversion NOT taking effect, and the incorrect value return will cause various system timer issue, like RCU stall etc.. Remove the additional brackets to make sure tpm_set_next_event always returns correct value. Fixes: 059ab7b82eec ("clocksource/drivers/imx-tpm: Add imx tpm timer support") Signed-off-by: Anson Huang Signed-off-by: Thomas Gleixner Acked-by: Dong Aisheng Cc: stable@vger.kernel.org Cc: daniel.lezcano@linaro.org Cc: Linux-imx@nxp.com Link: https://lkml.kernel.org/r/1524117883-2484-1-git-send-email-Anson.Huang@nxp.com --- drivers/clocksource/timer-imx-tpm.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/clocksource/timer-imx-tpm.c b/drivers/clocksource/timer-imx-tpm.c index 05d97a6871d8..6c8318470b48 100644 --- a/drivers/clocksource/timer-imx-tpm.c +++ b/drivers/clocksource/timer-imx-tpm.c @@ -114,7 +114,7 @@ static int tpm_set_next_event(unsigned long delta, * of writing CNT registers which may cause the min_delta event got * missed, so we need add a ETIME check here in case it happened. */ - return (int)((next - now) <= 0) ? -ETIME : 0; + return (int)(next - now) <= 0 ? -ETIME : 0; } static int tpm_set_state_oneshot(struct clock_event_device *evt) -- 2.30.2