From 87e57399e9d3606b08b0e1b2dd0f4aaa1d8ba365 Mon Sep 17 00:00:00 2001 From: Thadeu Lima de Souza Cascardo Date: Mon, 25 Jan 2016 11:29:19 -0200 Subject: [PATCH] sit: set rtnl_link_ops before calling register_netdevice When creating a SIT tunnel with ip tunnel, rtnl_link_ops is not set before ipip6_tunnel_create is called. When register_netdevice is called, there is no linkinfo attribute in the NEWLINK message because of that. Setting rtnl_link_ops before calling register_netdevice fixes that. Signed-off-by: Thadeu Lima de Souza Cascardo Signed-off-by: David S. Miller --- net/ipv6/sit.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/net/ipv6/sit.c b/net/ipv6/sit.c index e794ef66a401..2066d1c25a11 100644 --- a/net/ipv6/sit.c +++ b/net/ipv6/sit.c @@ -201,14 +201,14 @@ static int ipip6_tunnel_create(struct net_device *dev) if ((__force u16)t->parms.i_flags & SIT_ISATAP) dev->priv_flags |= IFF_ISATAP; + dev->rtnl_link_ops = &sit_link_ops; + err = register_netdevice(dev); if (err < 0) goto out; ipip6_tunnel_clone_6rd(dev, sitn); - dev->rtnl_link_ops = &sit_link_ops; - dev_hold(dev); ipip6_tunnel_link(sitn, t); -- 2.30.2