From f0af34317f4ba30794a19fd6ad7e30e801d53b07 Mon Sep 17 00:00:00 2001 From: Sean Wang Date: Fri, 15 Dec 2017 12:47:01 +0800 Subject: [PATCH] net: dsa: mediatek: combine MediaTek tag with VLAN tag In order to let MT7530 switch can recognize well those egress packets having both special tag and VLAN tag, the information about the special tag should be carried on the existing VLAN tag. On the other hand, it's unnecessary for extra handling for ingress packets when VLAN tag is present since it is able to put the VLAN tag after the special tag and then follow the existing way to parse. Signed-off-by: Sean Wang Reviewed-by: Andrew Lunn Signed-off-by: David S. Miller --- net/dsa/tag_mtk.c | 38 +++++++++++++++++++++++++++++--------- 1 file changed, 29 insertions(+), 9 deletions(-) diff --git a/net/dsa/tag_mtk.c b/net/dsa/tag_mtk.c index 8475434af7d5..11535bc70743 100644 --- a/net/dsa/tag_mtk.c +++ b/net/dsa/tag_mtk.c @@ -13,10 +13,13 @@ */ #include +#include #include "dsa_priv.h" #define MTK_HDR_LEN 4 +#define MTK_HDR_XMIT_UNTAGGED 0 +#define MTK_HDR_XMIT_TAGGED_TPID_8100 1 #define MTK_HDR_RECV_SOURCE_PORT_MASK GENMASK(2, 0) #define MTK_HDR_XMIT_DP_BIT_MASK GENMASK(5, 0) @@ -25,20 +28,37 @@ static struct sk_buff *mtk_tag_xmit(struct sk_buff *skb, { struct dsa_port *dp = dsa_slave_to_port(dev); u8 *mtk_tag; + bool is_vlan_skb = true; - if (skb_cow_head(skb, MTK_HDR_LEN) < 0) - return NULL; - - skb_push(skb, MTK_HDR_LEN); + /* Build the special tag after the MAC Source Address. If VLAN header + * is present, it's required that VLAN header and special tag is + * being combined. Only in this way we can allow the switch can parse + * the both special and VLAN tag at the same time and then look up VLAN + * table with VID. + */ + if (!skb_vlan_tagged(skb)) { + if (skb_cow_head(skb, MTK_HDR_LEN) < 0) + return NULL; - memmove(skb->data, skb->data + MTK_HDR_LEN, 2 * ETH_ALEN); + skb_push(skb, MTK_HDR_LEN); + memmove(skb->data, skb->data + MTK_HDR_LEN, 2 * ETH_ALEN); + is_vlan_skb = false; + } - /* Build the tag after the MAC Source Address */ mtk_tag = skb->data + 2 * ETH_ALEN; - mtk_tag[0] = 0; + + /* Mark tag attribute on special tag insertion to notify hardware + * whether that's a combined special tag with 802.1Q header. + */ + mtk_tag[0] = is_vlan_skb ? MTK_HDR_XMIT_TAGGED_TPID_8100 : + MTK_HDR_XMIT_UNTAGGED; mtk_tag[1] = (1 << dp->index) & MTK_HDR_XMIT_DP_BIT_MASK; - mtk_tag[2] = 0; - mtk_tag[3] = 0; + + /* Tag control information is kept for 802.1Q */ + if (!is_vlan_skb) { + mtk_tag[2] = 0; + mtk_tag[3] = 0; + } return skb; } -- 2.30.2